Open Access
Issue
EPJ Web Conf.
Volume 372, 2026
Advanced Power Systems (APS 2026)
Article Number 07016
Number of page(s) 6
Section Power and Energy Systems
DOI https://doi.org/10.1051/epjconf/202637207016
Published online 11 June 2026
  1. A. Seidman, H.W. Beaty, H. Mahrous, Handbook of Electric Power Calculations, Second Edition. New York: McGraw-Hill, 1996. [Google Scholar]
  2. Maier, S.G. Pavel, H.G. Beleiu, C.S. Pică, Considerations regarding the characterization and design of vertical earth grounding. În: Buletinul Științific al Conferinței de Inginerie Electrică și Sisteme „Ștefan Gârlașu”, Universitatea „Eftimie Murgu”, Reșița, 2016. [Google Scholar]
  3. V. Maier, S.G. Pavel, H.G. Beleiu, C.S. Pică, Vertical Earth Grounding Design Using Optimal Criteria, in Proceedings of 10th International Symposium on Advanced Topics in Electrical Engineering, ATEE 2017, Bucharest, March 23- 25, 2017. [Google Scholar]
  4. S.G. Pavel, V. Maier, C. Ciorca, H.G. Beleiu and I. Birou, Optimal Design of the Vertical Earthing with Electrodes Arranged in Line. Appl. Sci. 10 (3), 1177, 2076-3417(2020). [Google Scholar]
  5. V. Maier, S.G. Pavel, H.G. Beleiu, D.F. Niste, Dimensioning Aspects of Horizontal Earth Grounding, With Pipe Type Electrodes, in Proceedings of 13th International Symposium on Advanced Topics in Electrical Engineering, ATEE 2023, Bucharest, March 23-25, 2023, Bucharest, Romania. [Google Scholar]
  6. BS 7430:2011+A1:2015 Code of practice for protective earthing of electrical installations. [Google Scholar]
  7. *** Normativ pentru proiectarea, executarea şi exploatarea instalaţiilor electrice aferente clădirilor, I7-2011, vol. 1 şi 2. Bucureşti: MATRIX ROM, 2011. [Google Scholar]
  8. C. Ciorca, V. Maier, S.G. Pavel, H.G. Beleiu, Dimensioning of the Vertical Earth Grounding with Rectangular Contour through Minimizing the Investments Costs, in Proceedings of the International Conference and Exposition on Electrical and Power Engineering (EPE), Iași, (2018), 0154–0158. [Google Scholar]
  9. STAS 7334-83. Instalații electrice de IT. Instalații de legare la pământ de protecție. [Google Scholar]
  10. BS 7430:1998. Code of Practice for Earthing. [Google Scholar]
  11. BS 7430:2011+A1:2015 Code of practice for protective earthing of electrical installations. [Google Scholar]
  12. BS EN/IEC 62305 Lightning protection standard. [Google Scholar]
  13. *** Normativ pentru proiectarea, executarea şi exploatarea instalaţiilor electrice aferente clădirilor, I7-2011, vol. 1 şi 2. Bucureşti: MATRIX ROM, 2011. [Google Scholar]
  14. *** Îndreptar de proiectare și execuție a instalațiilor de legare la pământ, Indicativ 1 RE-Ip 30/2004. [Google Scholar]
  15. Ghid de bună practică pentru proiectarea instalațiilor de iluminat/protecție în clădiri, Indicativ Gex 12-2015. București: Editura MATRIX ROM, 2016. [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.