Issue |
EPJ Web Conf.
Volume 170, 2018
ANIMMA 2017 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications
|
|
---|---|---|
Article Number | 04023 | |
Number of page(s) | 7 | |
Section | Research reactors | |
DOI | https://doi.org/10.1051/epjconf/201817004023 | |
Published online | 10 January 2018 |
https://doi.org/10.1051/epjconf/201817004023
Reaction Rate Benchmark Experiments with Miniature Fission Chambers at the Slovenian TRIGA Mark II Reactor
Reactor Physics Department Jožef Stefan Institute Jamova cesta 19, SI-1000 Ljubljana
CEA, DEN, DER, Instrumentation, Sensors and Dosimetry Laboratory Cadarache, F-13108 St-Paul-Lez-Durance
email: ziga.stancar@ijs.si
email: loic.barbot@cea.fr
Published online: 10 January 2018
A series of fission rate profile measurements with miniature fission chambers, developed by the Commisariat á l’énergie atomique et auxénergies alternatives, were performed at the Jožef Stefan Institute’s TRIGA research reactor. Two types of fission chambers with different fissionable coating (235U and 238U) were used to perform axial fission rate profile measurements at various radial positions and several control rod configurations. The experimental campaign was supported by an extensive set of computations, based on a validated Monte Carlo computational model of the TRIGA reactor. The computing effort included neutron transport calculations to support the planning and design of the experiments as well as calculations to aid the evaluation of experimental and computational uncertainties and major biases. The evaluation of uncertainties was performed by employing various types of sensitivity analyses such as experimental parameter perturbation and core reaction rate gradient calculations. It has been found that the experimental uncertainty of the measurements is sufficiently low, i.e. the total relative fission rate uncertainty being approximately 5 %, in order for the experiments to serve as benchmark experiments for validation of fission rate profiles. The effect of the neutron flux redistribution due to the control rod movement was studied by performing measurements and calculations of fission rates and fission chamber responses in different axial and radial positions at different control rod configurations. It was confirmed that the control rod movement affects the position of the maximum in the axial fission rate distribution, as well as the height of the local maxima. The optimal detector position, in which the redistributions would have minimum effect on its signal, was determined.
© The Authors, published by EDP Sciences, 2018
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (http://creativecommons.org/licenses/by/4.0/).