Issue |
EPJ Web Conf.
Volume 203, 2019
20th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC20)
|
|
---|---|---|
Article Number | 01007 | |
Number of page(s) | 5 | |
DOI | https://doi.org/10.1051/epjconf/201920301007 | |
Published online | 25 March 2019 |
https://doi.org/10.1051/epjconf/201920301007
Theory
EC absorption efficiency in ITER at one-third nominal magnetic field strength
Istituto di Fisica del Plasma - CNR 20125 Milano Italy
* Corresponding author: micheletti@ifp.cnr.it
Published online: 25 March 2019
During the first phase of the ITER Pre-Fusion Power Operations (PFPO-1), the Electron Cyclotron Radio Frequency system will be the main heating and current drive source [1]. Evaluations of the L-H power threshold [2] have shown that H-mode is unlikely to be achieved in PFPO-1 scenarios at half-field (B0=2.65T). For this reason, the use of one-third field scenarios in an early phase might help to access H-mode. This means that the EC Heating (ECH) system, with gyrotrons operating at 170 GHz, would then rely on n=3 harmonic resonance. Using a lower frequency, namely 104 GHz, could allow the exploitation of n=2 harmonic resonance, improving heating efficiency and facilitating EC-assisted breakdown which has not been demonstrated yet for n=3 harmonic. This work presents a preliminary evaluation of the performances of an EC system using the two frequencies in a B0=1.8T scenario (obtained by adequately rescaling a reference half-field scenario [3]) via a parametric scan of density/temperature profiles, to cover the range of possible values expected to occur during the operations and provide an estimation of the parameter space region where the use of each frequency allows a good absorption efficiency.
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.