Issue |
EPJ Web Conf.
Volume 203, 2019
20th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC20)
|
|
---|---|---|
Article Number | 03008 | |
Number of page(s) | 6 | |
Section | Diagnostics | |
DOI | https://doi.org/10.1051/epjconf/201920303008 | |
Published online | 25 March 2019 |
https://doi.org/10.1051/epjconf/201920303008
Overview of the ECE measurements on EAST
1
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China
2
CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK
3
Department of Applied Science, University of California at Davis, Davis, California 95616, USA
4
University of Science and Technology of China, Hefei 230026, China
5
Institute for Fusion Studies, University of Texas at Austin, TX 78712, USA
6
CNR, Istituto di Fisica del Plasma, Milano 20125, Italy
* e-mail: liuyong@ipp.ac.cn
Published online: 25 March 2019
Radiometer systems and a Michelson interferometer, have been operated routinely to detect the elec-tron cyclotron emission (ECE) from EAST plasmas for diagnosing the local electron temperature. A common quasi-optical antenna placed inside the vacuum vessel is employed to collect and focus the plasma emission, and the line of sight is along a radial chord. All of the systems are located in a diagnostic room where the plasma emission is transmitted by overmoded corrugated waveguide. In-situ absolute intensity calibration has been carried out for both the radiometer systems and the Michelson interferometer independently, to ensure that the ECE diagnostic provides an independent electron temperature measurement. In order to diagnose the small-amplitude electron temperature fluctuation, a correlation ECE (CECE) diagnostic has been designed and commissioned recently. The CECE diagnostic employs an independent antenna system which has improved poloidal resolution. A synthetic diagnostic is realized by using the simulation code SPECE to interpret the ECE data in plasmas with non-Maxwellian distribution, and preliminary results imply that the ECE data could be still useful as a localized measurement in plasmas with non-thermal electrons, such as the LHW-heated plasmas on EAST.
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.