Issue |
EPJ Web Conf.
Volume 214, 2019
23rd International Conference on Computing in High Energy and Nuclear Physics (CHEP 2018)
|
|
---|---|---|
Article Number | 01032 | |
Number of page(s) | 8 | |
Section | T1 - Online computing | |
DOI | https://doi.org/10.1051/epjconf/201921401032 | |
Published online | 17 September 2019 |
https://doi.org/10.1051/epjconf/201921401032
The Continuously Running iFDAQ of the COMPASS Experiment
1
Technical University of Munich,
Germany
2
CERN,
Geneva
Switzerland
3
Charles University,
Prague
Czech Republic
4
Czech Technical University,
Prague,
Czech Republic
5
Joint Institute for Nuclear Research,
Dubna
Russia
* e-mail: ondrej.subrt@cern.ch
Published online: 17 September 2019
Recently, a stability of Data Acquisition System (DAQ) has become a vital precondition for a successful data taking in high energy physics experiments. The intelligent, FPGA-based Data Acquisition System (iFDAQ) of the COMPASS experiment at CERN is designed to be able to readout data at the maximum rate of the experiment and runsin a mode without any stops. DAQ systems fulfilling such requirements reach the efficiency up to 99%. The newly introduced continuously running mode enables to collect data without a necessity of any other user intervention.Such mode affects all processes of the iFDAQ with high emphasis on timing and precise synchronization. However, every undesirable interruption of data taking can potentially result in a possible loss of physics data. Running24/7 puts stress on reliability and robustness of the system. Therefore, the improvement of the iFDAQ stability had to come first. The continuously running mode and the improved iFDAQ stability helped to collect more physicsdata in the Run 2017. In the paper, we present the continuously running mode in more detail and discuss the overall iFDAQ stability.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.