ENHANCEMENT OF VALIDATION STUDIES FOR REACTOR DOSIMETRY AND ACTIVATION PREDICTIONS WITH THE NUCLEAR DATA SAMPLING METHODOLOGY
Paul Scherrer Institut Forschungsstrasse 111, 5232 Villigen PSI, Switzerland
alexander.vasiliev@psi.ch
marco.pecchia@psi.ch
dimitri-alexandre.rochman@psi.ch
hakim.ferroukhi@psi.ch
Published online: 22 February 2021
The CASMO/SIMULATE/MCNP/FISPACT-II calculation route has been established at the Paul Scherrer Institute (PSI) for reactor dosimetry and activation studies. Furthermore, the in-house tool NUSS is in use at PSI for nuclear data (ND) related uncertainties quantifications with Monte Carlo neutron transport calculations. The use of randomly sampled ACE-formatted ND files not only allows propagation of the ND uncertainties, but also can serve for assessing the applicability of different types of experimental data for validation of calculation predictions of parameters of interest. In the present work an application of the PSI calculation scheme for analysis of activation reaction rates and the fast neutron fluence (FNF), throughout the Swiss pressurised water reactor (PWR) and simplified containment building models, is demonstrated. As particular examples of potentially available experimental data, two kinds of the neutron flux monitors are considered: a) the reactor pressure vessel scraping samples and detectors placed in the dosimetry channels, mounted at the core barrel and designed for validation of FNF calculations, and b) the ex-vessel dosimeters, specifically used by the Swiss waste management organisation (NAGRA) for validation of bio-shield activation predictions. The calculations were done with the ENDF/B-VII.1 library. The obtained results demonstrate importance of the ND uncertainties for the dosimetry evaluations. The assessment of the applicability of the selected experimental information for validation of the bio-shield irradiation calculations was done based on evaluation of the ND-related Pearson correlation coefficients.
Key words: Reactor dosimetry / Concrete bio-shield / Validation / Uncertainties / Correlations
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.