This paper presents the concept of an active dosimetry system and its operational regime for pulsed radiation dose rate measurements. The plastic scintillator is suggested to be used for absorbed dose rate measurements. As long as the detector can be considered tissue equivalent, the energy weighting of pile-up events in terms of the dose is achieved. The real-time distinction of pulsed and non-pulsed dose rate contributions is based on the time structure of a single interaction and requires only basic information about the beam time structure (pulses duration and period). The detector connected to a fully digital signal processing board creates an active dosimetry system with adjustable parameters. Such a system was used for absorbed dose rate measurements in pulsed photon field mimicking radiation field outside the bunker of a medical LINAC, but also in the presence of a constant radiation component. The results show a linear dependence of a pulsed radiation contribution on the accelerator current in the investigated range of the total dose rate up to 8 μGy/h.
Key words: Active dosimetry / Plastic scintillator / Pulsed radiation / Radiation monitoring
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.