On the energy resolution of a GaAs-based electron source for spin-resolved inverse photoemission
1
Laboratoire de Physique des Solides, 91400 Orsay, France.
2
Constructive Solutions for Science and Technology, 33649 Bielefeld, Germany.
* Corresponding author: campos-contreras@lps.u-psud.fr
Published online: 2 December 2022
The spin resolution in inverse photoemission spectroscopy is achieved by injecting spin-polarized electrons, usually produced by GaAs-based cold cathodes that replace hot-filament electron guns of spin-integrated setups. The overall energy resolution of the system can be enhanced by adjusting either the optical bandpass of the photon detector or the energy distribution of the electron beam. Here we discuss the influence of the photocurrent and the photocathode temperature on the energy broadening of the electron beam through the inverse photoemission spectra of the spin-splitted Shockley surface state of Au(111). First, we find that cooling down the GaAs photocathode to 77 K increases the band gap and reduces the number of allowed vertical transitions, monochromatizing the electron beam with an enhancement of about 30 meV for the energy resolution. Second, we observe a correlation between the generated photocurrent at the electron source, and the space-charge effects at the sample as a reduction of lifetime and spin asymmetry of a polarized bulk state. These observations allow defining a threshold of current density for the optimum acquisition in the measurements of spin-resolved inverse photoemission in Au.
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.