Issue |
EPJ Web Conf.
Volume 283, 2023
Ultra High Energy Cosmic Rays (UHECR 2022)
|
|
---|---|---|
Article Number | 06013 | |
Number of page(s) | 4 | |
Section | Present and Future Detection and Analysis Techniques | |
DOI | https://doi.org/10.1051/epjconf/202328306013 | |
Published online | 28 April 2023 |
https://doi.org/10.1051/epjconf/202328306013
The XY-Scanner for Absolute End-to-End Calibration of Fluorescence Detectors
Palacký University, Faculty of Science, Joint Laboratory of Optics of Palacky University and Institute of Physics of CAS, 17. listopadu 12, 771 46, Olomouc, Czech Republic
* Corresponding author: martin.vacula@upol.cz
** Corresponding author: spokespersons@auger.org
Published online: 28 April 2023
The precise determination of the energy scale is a key part of experiments in astroparticle physics. At the Pierre Auger Observatory, the energy scale is set by the calorimetric measurement of extensive air showers with fluorescence detectors. Thus, the absolute end-to-end calibration of the fluorescence detectors is of utmost importance. In the past, this calibration was performed by illuminating the whole optical system of a fluorescence telescope with a large-scale extended uniform light source of the same diameter as the telescope aperture. However, handling difficulties, excessive manpower requirements, and degradation of such a source led to the need for a different approach for the absolute end-to-end calibration. The fundamental idea of the novel approach is to significantly reduce the geometrical size of the calibration light source, which is a near-UV LED source implemented in a portable integrating sphere with specifically designed interior. This light source is moved over the aperture by a rail mechanism with two independent linear stages named the XY-Scanner. Calibration data are evaluated from a series of light source positions instead of illuminating the entire aperture at once. The absolute photometric determination of the light source emission intensity is performed in a dedicated laboratory setup with a measurement uncertainty of 3.5 %. The XY-Scanner mechanics installed at the aperture gives also the opportunity to install other, devices for instance a narrow, collimated beam source to investigate local impurities of the telescopes. This contribution gives an overview of this novel XY-Scanner calibration method and presents preliminary results and discusses plans for the future.
Observatorio Pierre Auger, Av. San Martín Norte 304, 5613 Malargüe, Argentina
Full author list: https://www.auger.org/archive/authors_2022_10.html
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.