Issue |
EPJ Web Conf.
Volume 286, 2023
European Conference on Neutron Scattering 2023 (ECNS 2023)
|
|
---|---|---|
Article Number | 03008 | |
Number of page(s) | 10 | |
Section | Instrumentation | |
DOI | https://doi.org/10.1051/epjconf/202328603008 | |
Published online | 09 October 2023 |
https://doi.org/10.1051/epjconf/202328603008
Conceptual design of supermirror polarizers at the European Spallation Source
1 European Spallation Source ERIC, Partikelgatan 2, 22484 Lund, Sweden
2 Technical University of Denmark, Anker Engelunds Vej 101, 2800 Kongens Lyngby, Denmark
3 Lund University, Division of Materials Engineering, Ole Römers väg 1, 22363 Lund, Sweden
4 ESS-Bilbao, Parque Laida Bidea, Edificio 207-B, 48160 Derio, Spain
* Corresponding author: damian.rodriguez@ess.eu
Published online: 9 October 2023
Polarized neutrons will be made available on many European Spallation Source (ESS) instruments. There are a number of technologies available for polarizers and polarization analyzers which will be used at the ESS. The selection of the technology for an instrument is based on the performance and the constraints of the instrument. We will focus on the design of polarizing supermirror devices using Monte Carlo ray tracing simulation as an integral part of instrument design process. A McStas module has been developed to simulate a multichannel V-cavity polarizer, seeking the appropriate parameters to be incorporated into the respective instrument. The performance of such polarizers is studied for three instruments at ESS (MIRACLES (backscattering spectrometer), BIFROST (indirect geometry spectrometer) and ODIN (imaging)) with different requirements and constraints, where the suitability of this kind of devices can be assessed. For the first two instruments, where there is no strong constraint on the placement of the polarizer, the optimal configurations show excellent performance over the whole required wavelength ranges. However, in ODIN, due to more strict constraints in the placement of the polarizer, the performance is more dependent on the wavelength in the required wavelength range and other options may need to be considered.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.