Issue |
EPJ Web of Conf.
Volume 299, 2024
EFM22 – Experimental Fluid Mechanics 2022
|
|
---|---|---|
Article Number | 01040 | |
Number of page(s) | 5 | |
Section | Contributions | |
DOI | https://doi.org/10.1051/epjconf/202429901040 | |
Published online | 04 July 2024 |
https://doi.org/10.1051/epjconf/202429901040
Experimental set-up for the validation of phase change models in case of direct and inverse heat transfer problems
Brno University of Technology, Faculty of Mechanical Engeneering, Energy Institute, Technická 2896/2, 61669 Brno, Czech Republic
* e-mail: 162098@vutbr.cz
Published online: 4 July 2024
A number of models and modelling approaches for phase transitions of phase change materials (PCMs) have been proposed in recent years. However, many of these models have not been thoroughly validated with experimental data. This is in particular the case of the models for thermal hysteresis and partial phase transitions of PCMs, where the design and execution of relevant experiments is difficult. The most widely used experimental techniques for characterization of PCMs - Differential Scanning Calorimetry (DSC) and T-history method – require minimization of the temperature gradients in the test samples and thus the obtained results do not represent very well the behavior of PCMs in thermal energy storage (TES) systems (where large temperature gradients in PCMs are commonplace). An experimental set-up for the acquisition of data suitable for validation of phase change models have been proposed and assembled. The set-up can be used for the model validation in case of both the direct and inverse heat transfer problems. The set-up is based on the monitoring of the phase change front propagation in a rectangular cavity, where the positive or negative heat flux is introduced at one of the cavity walls. Such an arrangement results in (often significant) temperature gradients in a PCM. Unlike in similar experimental set-ups, where a heat transfer fluid (HTF) is used to introduce the heat flux at the wall, the Peltier cells are used in the proposed experimental set-up for this purpose. Also, most experiments reported in the literature only addressed the melting process (heating of a PCM) with the positive heat flux introduced at the wall. The Peltier cells allow for relatively quick switching between the positive and negative heat flux (heating/cooling) and as a result the thermal processes similar to real-life operation of TES systems can be investigated. The cubical cavity with 250 mm long internal edges is made of PMMA. The wall, at which the heat flux is introduced, is made of a 15 mm thick aluminum plate with embedded RTD temperature sensors for wall temperature monitoring. A heat flux sensor is installed on the side of the aluminum plate facing the PCM (the heat flux sensor covers the entire surface of the plate). An extended heat transfer surface in the form of a finned aluminum sink is installed on the Peltier cells to improve the heat transfer between the cells and the ambient environment.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.