Issue |
EPJ Web Conf.
Volume 305, 2024
6th International Conference on Applications of Optics and Photonics (AOP2024)
|
|
---|---|---|
Article Number | 00004 | |
Number of page(s) | 5 | |
DOI | https://doi.org/10.1051/epjconf/202430500004 | |
Published online | 15 October 2024 |
https://doi.org/10.1051/epjconf/202430500004
Enzymatic Plasmonic Optical Fiber Biosensor for Uric Acid Detection
1 i3N, Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal
2 IEETA, DETI, LASI, University of Aveiro, 3810-193 Aveiro, Portugal
* Corresponding author: sonia.pereira@ua.pt
Published online: 15 October 2024
Uric acid plays important roles in the body, acting as an antioxidant, contributing to the elimination of metabolic waste, and helping to combat some infections. Alterations in uric acid concentration can be important indicators of disease and their real-time and point-of-care monitoring is of extreme importance, for instance in primary care facilities. Optical fibre biosensors are a promising option, allowing real-time detection, quantification, and monitoring of uric acid concentrations in blood plasma or urine. In this work, enzymatic plasmonic sensors were developed for the detection of uric acid using multimode optical fibres composed of a 400 µm silica core and a polymer cladding. To prepare the sensors, the coating and cladding were removed from a section at the fibre tip, and nano film of gold was deposited on their surface, obtaining gold-coated sensors at the fibre tips (Au-tips). Initially, the sensor was characterized to bulk refractive index, exhibiting a sensitivity of 1420.7 ± 59.8 nm/RIU. The Au-tip was biofunctionalized with the enzyme uricase and detection tests were carried out. Uric acid detection tests revealed a response consistent with the Michaelis-Menten function, which was employed to assess the enzymatic kinetics of uricase immobilized on the Au-tips.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.