Issue |
EPJ Web Conf.
Volume 313, 2024
22nd Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC22)
|
|
---|---|---|
Article Number | 04003 | |
Number of page(s) | 6 | |
Section | Technology | |
DOI | https://doi.org/10.1051/epjconf/202431304003 | |
Published online | 15 November 2024 |
https://doi.org/10.1051/epjconf/202431304003
ITER ECH&CD Transmission Line Layout Development
Oak Ridge National Laboratory, Oak Ridge, TN 37931, USA
* Corresponding author : wolfezc@ornl.gov
Published online: 15 November 2024
A primary contributor to the effectiveness of the ITER electron cyclotron (EC) heating & current drive (H&CD) transmission line (TL) is the distortion of the waveguide which has a strong, direct correlation with power transmission efficiency and electromagnetic mode purity. Two main sources of distortion are the deflection of the TL due to operational loads and misalignment of the waveguide supports. To address these and other interdependent variables, the EC TL design focused on a holistic method to provide iterative simultaneous development of the system and microwave components. The process provided close, rapid interconnectivity between the prescribed subsystem requirements and the design activities being performed, including a detailed 3D configuration management model, a system structural finite element analysis, a thorough multi-sample Monte-Carlo system functional performance assessment, and individual microwave component designs & analyses. This paper intends to provide an overview of the first of these: the design development process of the TL layout. This includes investigating the inputs into layout optimization, the overall integration process, the interconnectivity with the other design activities, and their impacts on TL subsystem performance that ultimately resulted in the current baseline layout.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.