Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge
1 University of Torino, Department of Physics, Torino, Italy
2 Istituto Nazionale di Fisica Nucleare (INFN), Section of Torino, Torino, Italy
* e-mail: alessandro.valetti@unito.it
Published online: 7 March 2025
The precision of clinical treatment planning systems for particle therapy is limited (among other reasons) by the absence of measurements on the differential fragmentation cross sections generated during interactions between light ions (such as C and O) and hydrogen-enriched targets. To address this issue, the FOOT experiment has been designed to take data for beam energies up to 400 MeV/u using an inverse kinematics approach. By extending the energy range to 800 MeV/u, FOOT will also collect valuable data to optimize the design of spacecraft shielding [1]. The experiment aims at identifying fragments by measuring their momentum, kinetic energy, and time of flight with high resolution: 5%, 2% and <100 ps respectively. A calorimeter detector made of 320 BGO crystals coupled to SiPM photodetectors, covering a dynamic range from tens of MeVs to about 10 GeV, measures the kinetic energy. A series of data taking campaigns aiming at characterizing, optimizing and equalizing the crystals response have been conducted at HIT (Heidelberg, Germany) and CNAO (Pavia, Italy). The measurements confirm an integral energy resolution well below the goal of 2%. The modified Birks-energy-response-function shows an excellent agreement with the response of the crystals between 50 and 430 MeV/u for all the ions, although a dependence of the parameters on Z is observed. In this work, the equalization strategy needed to properly measure the fragments kinetic energy and masses in combination with the ToF detectors will be presented.
© The Authors, published by EDP Sciences, 2025
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.