Open Access
Issue |
EPJ Web Conf.
Volume 288, 2023
ANIMMA 2023 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications
|
|
---|---|---|
Article Number | 05004 | |
Number of page(s) | 5 | |
Section | Nuclear Power Reactors and Nuclear Fuel Cycle | |
DOI | https://doi.org/10.1051/epjconf/202328805004 | |
Published online | 21 November 2023 |
- R. N. Sah and P. H. Brown, “Boron Determination—A Review of Analytical Methods, ” Microchemical Journal, vol. 56, no. 3, pp. 285-304, 1997/07/01, doi: 10.1006/mchj.1997.1428. [CrossRef] [Google Scholar]
- C. Kong, H. Lee, T. Tak, D. Lee, S. H. Kim, and S. Lyou, “Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-Detector, ” (in English), Nucl Eng Technol, vol. 48, no. 6, pp. 1360-1367, Dec 2016, doi: 10.1016/j.net.2016.06.012. [CrossRef] [Google Scholar]
- S. H. Sung and H. R. Kim, “Development of accuracy enhancement system for boron meters using multisensitive detector for reactor safety, ” (in English), Nucl Eng Technol, vol. 52, no. 3, pp. 538-543, Mar 2020, doi: 10.1016/j.net.2019.08.004. [CrossRef] [Google Scholar]
- S. H. Sung and H. R. Kim, “Experimental characterization of the accuracy of multidetector boron meter for operational safety of reactors, ” (in English), Int J Energ Res, vol. 42, no. 8, pp. 2701-2709, Jun 25 2018, doi: 10.1002/er.4059. [CrossRef] [Google Scholar]
- S. H. Sung, U. J. Lee, J. S. Min, and H. R. Kim, “Experimental Setup for Boron Meter Accuracy Analysis in Nuclear Reactor Environment, ” (in English), Materials in Environmental Engineering, pp. 1201-1207, 2017, doi: 10.1515/9783110516623-118. [Google Scholar]
- J. Bulkowski, W. Fletcher, A. Opitz, V. Rajagopal, and D. Whyte, “DEVELOPMENT OF A BORON CONCENTRATION METER. Final Report, ” Westinghouse Electric Corp., Pittsburgh, Pa. Nuclear Energy Systems Div., 1969. [Google Scholar]
- Y. Jo, C. Kong, J. Yu, D. Lee, and S. H. Kim, “High accuracy boronometer design developed for light water reactors, ” Ann Nucl Energy, vol. 110, pp. 25-30, 2017. [CrossRef] [Google Scholar]
- P. M. Dighe, “Design simulation studies of pipe mounted boron concentration meter, ” (in English), Ann Nucl Energy, vol. 134, pp. 414-423, Dec 2019, doi: 10.1016/j.anucene.2019.07.021. [CrossRef] [Google Scholar]
- Framatome. “Boronline®, A new generation of boron meter. Technical Sheet No: A3022.” (accessed April 15, 2022). [Google Scholar]
- Mirion Technologies. “BM501TM, Boronmeter. Technical Sheet No: 155780EN-F.” https://www.mirion.com/products/bm-501-boron-meter (accessed November 23, 2021). [Google Scholar]
- P. Pirat, “Boronline, a new generation of boron meter, ” in 2011 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications, 2011: IEEE, pp. 1-2. [Google Scholar]
- M. Jimenez and P. Pirat, “CONTINUOUS MEASUREMENT OF BORON CONCENTRATION IN NUCLEAR POWER PLANTS: WHY IS IT ESSENTIAL FOR SAFE AND EFFICIENT OPERATION?, ” 2017. [Google Scholar]
- C. J. Werner et al., “MCNP6.2 Release Notes”, Los Alamos National Laboratory, report LA-UR-18-20808, 2018. [Google Scholar]
- PHOTONIS. “CPNB48 Specifications.” https://www.photonis.com/system/files/2019-03/CPNB48-specifications.pdf (accessed April 28, 2022). [Google Scholar]
- J. J. Duderstadt and L. J. Hamilton, Nuclear reactor analysis. Wiley, 1976. [Google Scholar]
- M. Coste-Delclaux, C. Diop, A. Nicolas, and B. Bonin, Neutronics. CEA Saclay; Groupe Moniteur, 2015. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.