- F. Kuntz, A. Nasreddine, N. Ludwig, et A. Strasser, « Feerix, a Novel Irradiation Platform for R&D, Education and Training », 2022. [Google Scholar]
- L. Tasinato et D. Tisseur, « Development of a method for the on-line spectral characterization of Bremsstrahlung photons from an electron accelerator », Radiation Physics and Chemistry, vol. 215, p. 111374, févr. 2024, doi: 10.1016/j.radphyschem.2023.111374. [Google Scholar]
- B. Armbruster, R. J. Hamilton, et A. K. Kuehl, « Spectrum reconstruction from dose measurements as a linear inverse problem », Phys. Med. Biol., vol. 49, no 22, p. 5087, oct. 2004, doi: 10.1088/0031-9155/49/22/005. [Google Scholar]
- B. Juste, R. Miró, G. Verdú, S. Díez, et J. M. Campayo, « Linac photon spectra reconstruction using a depth dose gradient TSVD methodology based on Monte Carlo simulation », in 2011 4th International Conference on Biomedical Engineering and Informatics (BMEI), oct. 2011, p. 786–790. doi: 10.1109/BMEI.2011.6098411. [Google Scholar]
- B. Juste, R. Miró, G. Verdú, S. Díez, et J. M. Campayo, « Bremsstrahlung Spectrum Reconstruction from Gradient Depth Dose Curves Obtained in a Water Phantom », Nuclear Technology, vol. 175, no 1, p. 175–181, juill. 2011, doi: 10.13182/NT11-A12287. [Google Scholar]
- Z. Shafahi, S. Sina, et R. Faghihi, « Comparison of TSVD, MTSVD, and Tikhonov unfolding methods for reconstruction of X-ray spectra », Radiation Physics and Chemistry, vol. 166, p. 108437, janv. 2020, doi: 10.1016/j.radphyschem.2019.108437. [Google Scholar]
- J. Torres-Díaz, G. B. Grad, et E. V. Bonzi, « Measurement of linear accelerator spectra, reconstructed from percentage depth dose curves by neural networks », Physica Medica, vol. 96, p. 81–89, avr. 2022, doi: 10.1016/j.ejmp.2022.02.019. [Google Scholar]
- S. Jan et al., « GATE: a simulation toolkit for PET and SPECT », Phys Med Biol, vol. 49, no 19, p. 4543–4561, oct. 2004, doi: 10.1088/0031-9155/49/19/007. [Google Scholar]
- ISO 11137-1:2006. Sterilization of health care products — Radiation — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices. International Organization for Standardization, Geneva. [Google Scholar]