Assessment of Efficiency of Regenerative Heating System of Feed Water for High Temperature Turbine Plant on Decentralized Power Engineering Facilities
National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
a Corresponding author: laryk070@gmail.com
Published online: 23 February 2016
The results of theoretical researches on efficiency of air heater use have been presented. The results of the research show the possibility of increase of energy efficiency of electrical power unit on electrical energy consumption by 2% at the initial temperature of steam 1073 K. The possibility of decrease of unit consumption of reference fuel by 4% has been stated.
© Owned by the authors, published by EDP Sciences, 2016
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.