SCALE/MAVRIC calculation of dose rates measured for a gamma radiation source in a thick-walled transport and storage cask of ductile cast iron with lead inserts
1 Bundesamt für kerntechnische Entsorgungssicherheit (BfE), Postfach 100149, 38201 Salzgitter, Germany
2 WTI Wissenschaftlich-Technische Ingenieurberatung GmbH, Karl-Heinz-Beckurts-Straße 8, 52428 Jülich, Germany
a Corresponding author: Werner.Baumgarten@BfE.bund.de
Published online: 25 September 2017
Dose rate calculations are important for judging the shielding performance of transport casks for radioactive material. Therefore it is important to have reliable calculation tools. We report on measured and calculated dose rates near a thick-walled transport and storage cask of ductile cast iron with lead inserts and a Co-60 source inside. In a series of experiments the thickness of the inserts was varied, and measured dose rates near the cask were compared with SCALE/MAVRIC 6.1.3 and SCALE/MAVRIC 6.2 calculation results. Deviations from the measurements were found to be higher for increased lead thicknesses. Furthermore, it is shown how the shielding material density, air scattering and accounting for the floor influence the quality of the calculation.
© The Authors, published by EDP Sciences, 2017
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.