Issue |
EPJ Web Conf.
Volume 203, 2019
20th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC20)
|
|
---|---|---|
Article Number | 02009 | |
Number of page(s) | 6 | |
Section | Experiment | |
DOI | https://doi.org/10.1051/epjconf/201920302009 | |
Published online | 25 March 2019 |
https://doi.org/10.1051/epjconf/201920302009
Beam tracing study for design and operation of two-pass electron cyclotron heating at ASDEX Upgrade
1
Max Planck Institute for Plasma Physics Boltzmannstr.2 85748 Garching Germany
2
Institut für Grenzflächenverfahrenstechnik und Plasmatechnologie, Universität Stuttgart , Pfaffenwaldring 31 70569 Stuttgart Germany
* Corresponding author: Martin. Schubert @ ipp. mpg. de
Published online: 25 March 2019
The electron cyclotron resonance heating system at ASDEX Upgrade (AUG) is currently being extended to eight similar Gyrotrons in total. Each Gyrotron operates at 105 and 140 GHz and is designed for up to 1 MW millimetre wave output power. A substantial part of the AUG program will focus on experimental conditions, where the plasma density may be above the X-2 cut-off density at 140 GHz. In order to cope with the high density, the heating system will operate in the O-2 mode scheme with potentially incomplete absorption in the first pass. Reflecting gratings installed into the heat shield on AUG’s inner column allow for a controlled second pass of the beam’s unabsorbed fraction. Thermocouple measurements serve to control the beam position on the grating. The beam geometry is being finalized for the launchers #1-4. Beam propagation is simulated with the TORBEAM code and previous high density experiments are used as a database. The geometry is optimized using three criteria: central deposition, high absorption and robustness of the beam dump after the second pass. The experimental conditions, and the plasma electron density in particular, may vary such that the Gaussian beam parameters of the incoming beam on the grating deviate from the design values. It is proposed to model the effect of the grating with an equivalent ellipsoidal mirror. Laboratory measurements are shown, which support this model.
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.