Development of a correlation ECE radiometer for electron temperature fluctuation measurements in Heliotron J
1
Max-Planck Institute for Plasma Physics, Greifswald, Germany
2
Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto, Japan
3
Zhejiang University, Hangzhou, China
4
Graduate School of Energy Science, Kyoto University, Uji, Kyoto, Japan
5
Southwestern Institute of Physics, Chengdu, China
6
National Institute for Fusion Science, Toki, Japan
* Corresponding author: nagasaki@iae.kyoto-u.ac.jp
Published online: 25 March 2019
A radial correlation ECE radiometer diagnostic has been developed for electron temperature fluctuation measurements in the helical-axis heliotron device, Heliotron J. The radiometer consists of two heterodyne detection systems. One system scans the frequency of a local oscillator from 52 to 64 GHz with a single intermediate frequency filter, and the second system has a fixed frequency, 56 GHz local oscillator with four intermediate frequency filters. This frequency range covers measurement positions spanning from the plasma core to the half radius. Laboratory tests indicate that each system has narrow intermediate frequency bandwidth and high-sensitivity over a large dynamic range. During plasma experiments with NBI heating, radiation temperature fluctuation measured by the CECE radiometer decrease with increasing ECCD commensurate with previous measurements of energetic particle driven modes on Heliotron J.
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.