Issue |
EPJ Web Conf.
Volume 203, 2019
20th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC20)
|
|
---|---|---|
Article Number | 03012 | |
Number of page(s) | 5 | |
Section | Diagnostics | |
DOI | https://doi.org/10.1051/epjconf/201920303012 | |
Published online | 25 March 2019 |
https://doi.org/10.1051/epjconf/201920303012
Developments for collective Thomson scattering equipment with a sub-THz gyrotron in LHD
1
Research Center for Development of Far-Infrared Region, University of Fukui, 3-9-1 Bunkyo, Fukui city, 910-8507, Japan
2
National Institute for Fusion Science, National Institute of Natural Sciences, 322-6 Oroshi cho, Toki city, 509-5292, Japan
3
Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa city, 277-8561, Japan
* Corresponding author: saito_2729@fir.u-fukui.ac.jp
Published online: 25 March 2019
Plan of collective Thomson scattering (CTS) experiment for the Large Helical Device (LHD) in NIFS with a 303 GHz gyrotron is under way. Use of a sub-THz gyrotron expands the CTS-applicable region of plasma parameters. In LHD, sub-THz CTS can be applied to the high density operation region, plasmas with impurity hole, etc. Moreover, sub-THz CTS is expected to be free from ECE noise. Its “collective” use with 77 GHz and 154 GHz CTS will compose a powerful diagnostic system. A high power sub-THz gyrotron with a frequency of 303 GHz has been developed. Its maximum power is 320 kW. It oscillates in pulse mode and the maximum pulse width is around 100 μs, which is sufficient for use in CTS experiments. A whispering gallery mode TE22,2 was adopted for this gyrotron to avoid mode competition. Careful frequency measurement has proved purely single mode oscillation of the TE22,2 mode including turn-on and turn-off phases of the oscillation pulse. This is consistent with mode competition calculations taking account of a finite voltage rise time. A low loss transmission line is necessary for CTS. We have two possibilities. One is a new line with 1.25 inch corrugated waveguides that are optimized for the 300 GHz band. Transmission test with the 303 GHz gyrotron has been carried out and a sufficiently low loss coefficient has been confirmed. The other is to use an existing line with 3.5 inch corrugated waveguides for lower frequencies such as 77 GHz and 154 GHz. Transmission test has been carried out with the 303 GHz gyrotron and a sufficiently low loss coefficient has been confirmed also for 3.5 inch corrugated waveguides. An existing line with 3.5 inch corrugated waveguides will be used in the initial phase of 303 GHz CTS experiment.
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.