CFD MODELLING OF INDUSTRIAL AIR CURTAINS WITH HEATING UNIT
Konya Technical University Department of Mechanical Engineering, Konya, Turkey.
* Corresponding author: muharremaksoy@selcuk.edu.tr
Published online: 28 June 2019
Industrial air curtains are used to prevent air from moving from one space to another space or to environment. The most common used type is downward-facing blower fan mounted over the entrance of a building, or an opening door between two spaces conditioned at different temperatures. In many factories and industrial buildings, heating or cooling applications are difficult due to the huge doors. These huge doors cause heat loses with convection phenomena of the inside air. In this study an air curtain having heater unit is analyzed numerically by CFD. The height of the air curtain from the bottom side is vary between 2.5 m, 3 m, 4m, 5m and 6 m mounted over the entrance door of the conditioned volume. For CFD studies proper mesh structure is created on the flow domain and Shear Stress Transport (SST) k-omega models were used in Unsteady Reynolds Averaged Navier-Stokes (URANS) computations. The blowing temperature of the air curtain has adjusted to 60 °C with the inside temperature was aimed to kept at +7°C while the outside temperature was -5°C. It is found that there is less flow occurred to the environment from conditioned volume at 2.5 3, 4 and 5 meter height cases. In these cases, the air curtain also contributes the heating of the conditioned room. But some ratio of the air flows through the atmosphere and the room cannot kept at the +7°C initial temperature at 6 m case. It is also found that the heating ratio at different blowing heights differs between 0,89-1,98 comparing the case without an air curtain.
Key words: air curtain / heating / SST k-ω / CFD / heating ratio
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.