Issue |
EPJ Web Conf.
Volume 219, 2019
International Workshop on Particle Physics at Neutron Sources (PPNS 2018)
|
|
---|---|---|
Article Number | 02002 | |
Number of page(s) | 8 | |
Section | Searches for a Permanent Electric Dipole Moment | |
DOI | https://doi.org/10.1051/epjconf/201921902002 | |
Published online | 12 December 2019 |
https://doi.org/10.1051/epjconf/201921902002
The n2EDM experiment at the Paul Scherrer Institute
1 University of Sussex, Brighton, UK
2 Normandie Univ, ENSICAEN, UNICAEN, CNRS/IN2P3, LPC Caen, Caen, France
3 Paul Scherrer Institute, 5232 Villigen, Switzerland
4 Jagiellonian University, Cracow, Poland
5 Instituut voor Kern- en Stralingsfysica, KU Leuven, 3001 Heverlee, Belgium
6 Laboratory for High Energy Physics and Albert Einstein Center for Fundamental Physics, University of Bern, Bern, Switzerland
7 Laboratoire de Physique Subatomique et de Cosmologie, Grenoble, France
8 University of Kentucky, Lexington, USA
9 Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland
10 Physics Department, University of Fribourg, 1700 Fribourg, Switzerland
11 Institut für Physik, Johannes-Gutenberg-Universität, Mainz, Germany
12 Henryk Niedwodniczański Institute for Nuclear Physics, Cracow, Poland
13 Institut für Kernchemie, Johannes-Gutenberg-Universität, Mainz, Germany
14 CSNSM, Université Paris Sud, CNRS/IN2P3, Université Paris Saclay, Orsay-Campus, France
15 Physikalisch Technische Bundesanstalt, Berlin, Germany
a e-mail: peter.koss@kuleuven.be/ ORCiD: 0000-0001-5094-3056
b e-mail: bernhard.lauss@psi.ch / ORCiD: 0000-0002-1986-391X
c e-mail: Present address: Michigan State University, East-Lansing, MI, USA
Published online: 12 December 2019
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.