Water content and iron oxidation state analysis of silicate glass using the electron probe
1 Volcanology Team, The New Zealand Institute for Earth Science Limited, Aotearoa New Zealand
2 Department of Earth Sciences, University College London, UK
3 School of Earth Sciences, University of Bristol, UK
4 Department of Earth Sciences, University of Oxford, UK
* Corresponding author: This email address is being protected from spambots. You need JavaScript enabled to view it.
Published online: 29 January 2026
The water content (H2O) and iron oxidation state (Fe3+/FeT) of silicate glass are useful compositional parameters to measure in volcanology and igneous petrology due to: (1) their influence on the chemical and physical properties of magmas, and (2) their use in constraining the pressure-temperature-composition conditions of magma storage and ascent. We present techniques using electron probe microanalysis (EPMA) that carefully mitigate for the effects of sub-surface charging, which causes beam damage and modifies X-ray emission. The calibrated volatiles-by-difference technique quantifies H2O (assuming that this is the dominant volatile species) in silicate glass at a spatial resolution of 5-10 μm diameter with uncertainties of ±0.5-0.7 wt% and has been tested on basaltic glasses. The time-dependent-ratio flank method quantifies Fe3+/FeT at a spatial resolution of 20-60 μm diameter with uncertainties of ±0.1 and has been tested on a wide range of basaltic and peralkaline rhyolitic glasses. EPMA often requires straightforward sample preparation and is more accessible than other techniques used to quantify both H2O and Fe3+/FeT (e.g., SIMS, FTIR, Raman, XANES, Mössbauer), although uncertainties are typically larger using EPMA. For H2O, the spatial resolution of EPMA is often higher than other techniques (e.g., SIMS, FTIR), whereas for Fe3+/FeT it is often lower (e.g., Raman, XANES). Both EPMA techniques can be used on natural (e.g., melt inclusion and matrix glass) and experimental glasses, in addition to standard EPMA for quantification of major and minor element concentrations, for extensive chemical characterisation using EPMA.
© The Authors, published by EDP Sciences, 2026
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.